Genetic Code

In the News..

28-11-2006

Datastick® DAS-1294 PDA data collection for research

The Datastick® DAS-1294 data acquisition modules bring a high level of reliability, convenience, and versatility to handheld instrumentation for test and measurement in research applications.

The Tommi Melon

Datastick® DAS-1254 and DAS-1294 data acquisition modules

Data acquisition modules for Palm Tungsten series and m500-series handhelds

Datastick DAS-1254 and DAS-1294 data acquisition modules for Palm Tungsten series handhelds and m500-series handhelds provide four (DAS-1254) or eight (DAS-1294) analog input channels, one digital counter, one digital input line, and two digital output lines. When used with Datastick Connection, Datastick Connection Lite, or Datastick Connection Plus software, these devices provide a complete, real-time data acquisition system

Based on the latest innovative designs from Datastick Systems, the Datastick® DAS-1254 and DAS-1294 data acquisition modules bring a new level of reliability, convenience, and versatility to handheld instrumentation for test and measurement.

Introduction

The DAS-1254 module has four single-ended analog inputs and the DAS-1294 has eight single-ended analog inputs. Each model provides one 16-bit digital counter, one TTL-level digital-switch input line, and two TTL-level digital-switch output lines.

Each module firmly attaches to any Palm™ Tungsten™ T, T2, T3, or C or Garmin iQue 3200 or iQue 3600 handheld. High-impedance inputs ensure compatibility with almost any active analog sensor. The new, integrated 20-pin connector features a harpoon latch for a more secure connection and is shielded for lower noise than the original DAS-1245.

Both models are powered by a pair of on-board AAA alkaline batteries or by an optional external power supply (see Accessories). Power management has been redesigned from the ground up to provide improved power consumption over the original DAS-1245.

The DAS-1254 and DAS-1294 include Datastick Connection Lite software for basic functionality right out of the box. Other software applications — Datastick Connection and Datastick Connection Plus — are sold separately and provide better performance, specialized features, and greater convenience.

The DAS-1254 and DAS-1294 data acquisition systems, hardware and software, are ideal for applications as varied as R&D, lab work, field testing, quality assurance, industrial control, environmental studies, and education, and they fit almost any budget.

Key Features

  • 12-bit resolution A-to-D
  • 4 analog inputs (DAS1254) or 8 analog inputs (DAS-1294)
  • 1 Mohm analog input impedance
  • 1 16-bit digital counter
  • 1 digital input line
  • 2 digital output lines
  • Real-time display up to 20 samples/sec. (Datastick Conection Lite, Datastick Connection, Datastick Connection Plus)
  • Self-powered or external power
  • +5 V power output to sensors
  • 4-20 mA input with optional cable or breakout module
  • Multirange inputs with optional accessories
  • Custom input ranges available on special order

Specification

  • Channels:4 (DAS-1254) or 8 (DAS-1294) analog inputs, 1 digital counter input, 1 digital input line, 2 digital output lines, analog ground, digital ground, +5V power output
  • Input Connector: 20-pin shielded DXM with harpoon lock
  • Analog Input Impedance: 1 MOhm
  • Analog Input Range: 0-5 V across 4 or 8 analog channels. 4-20 mA inputs and other voltage ranges with optional cable or breakout module; see Accessories page for signal conditioning options or contact Datastick for custom input ranges.
  • A-to-D Resolution: 12 bits
  • Analog Sample Rate: Up to 20 samples per second with real-time display
  • Voltage Reference accuracy: 0.2%
  • Sensor Power: 5V switchable, 20 mA max output current
  • Digital Counter: 10 kOhm pullup to 3.3V, TTL level inputs
  • Digital Input Line: 10 kOhm pullup to 3.3V, TTL level inputs
  • Digital Output Line: 10 kOhm pullup to 3.3V, TTL level inputs
  • Power Requirements: two AAA batteries or external regulated DC power input (5V @ 1A) see Accessories page for optional power supplies.
  • Battery Life: Battery life is directly related to sample rate. At lower sample rates, batteries will last longer. Extended measurement periods can use external power source.


Product Sheet download by clicking here